  • Butterfly_Stereopsis_Test_lg
    Designed to rapidly test for amblyopia and strabismus using gross thru fine stereopsis (2500 to 20 seconds of arc). Graded circle test from 400 seconds now down to 20 seconds with no monocular clues. New improved booklet has answer key on back cover and includes polarized viewers.
    • Graded circle test from 400 seconds now down to 20 seconds
    • No monocular clues with NEW Technology
    • New improved booklet
    • Answer key on back cover
    • Includes both adult and pediatric polarized viewers
  • Cardiff Acuity Test Set
    Cardiff Acuity Test Set™ with 36 cards and occluding glasses An upgrade for the Cardiff Acuity Test™ is now offered to meet the differing needs of Pediatric vs. Low Vision patients (Item #: NCATSLVU). The Low Vision upgrade kit includes a set of 3 cards each of levels A, LVB and LVA plus three red dividers. The standard set covers 12 acuity levels from 20/160 to 20/12.5. This version also include a pair of 4608R Butterfly foamy occluding glasses. The Low Vision set covers 14 levels from 20/320 to 20/12.5. There are three cards at each of these acuity levels. Intended for test distances of 1 meter and 50 cm. Cards are laminated and measure 7 3/4 by 10 1/2 in (20 by 27 cm) and are labeled by acuity level equivalents in decimal, meters, feet, Snellen and LogMAR for both test distances.
  • Fly_Stereopsis_Test_LEA_lg

    Designed to rapidly test for amblyopia and strabismus using gross thru fine stereopsis (4800 to 20 seconds of arc). Graded circle test from 400 seconds now down to 20 seconds with no monocular clues. New improved booklet has answer key on back cover and includes polarized viewers.

    • Graded circle test from 400 seconds now down to 20 seconds
    • No monocular clues with NEW technology
    • New improved booklet
    • Answer key on back cover
    • Includes both adult and pediatric polarized viewers
  • Frisby Stereo Test - 3 Plates
    All Frisby Stereo Test Present "real depth" objects viewed with natural vision: no testing glasses are required. Each plate has four random-pattern squares with a circle of pattern elements lying in depth relative to its surround. The depth effect is due to the circle and its surround being printed on opposite sides of the plate. The Frisby Stereo Test has 3 plates allowing for testing stereo acuity disparity as fine as 15 seconds of arc.
  • Frisby Stereotest Screening    frisby stereotests,  with no need for special glasses, and suitable for screening young children Made in UK
    Purpose  : To demonstrate stereopsis
    Age Range : About 6 months to adult
    Administration : About 1-5 minutes
  • HRR_Standard_Version
    Includes the four demonstration plates, the six screener plates and the 14 diagnostic series for a total of 24 plates. Each of these plates has its own tab for easy and clean page selection. The test also includes a set of instructions in English and a laminated copy of the score sheet. This test is good for detecting changes in vision as a side effect from pharmaceuticals. These are most likely to affect Blue/Yellow vision. Other tests for color vision may not be as good at detecting.
  • Ishihara_Test
      The Ishihara`s Tests for Colour Deficiency consist of four (4)different types, namely, The first type is the 38-Plate (Complete) Edition, used principally by Ophthalmologists in order to classify completely the type of colour deficiency.   The second type is the 24-plates (Abridged) Edition used principally at factories and offices of transportation and other concerned places of the purpose of conducting usual sample survey for colour deficiency in a short space of time when hiring new employees. The third type is the 14-plate (Concised) edition. On the average, charts of highest accuracy were selected from the 38 plate(Complete) Edition to conduct minimum examinations of colour deficiency. The forth type is the 10-plate for Unlettered persons Edition or the test for colour deficiency for infants.
  • RAF_Guage
    The RAF Binocular Gauge Keeler PN: 2301-L-1020 Made in UK Useful device for determining the objective and subjective convergence points, measuring accommodation and determining the dominant eye. Lightweight bar, 500mm in length on which a sliding four sided drum is mounted with different test on each panel.
  • Fixation_Bar
    Fixation Bar - Budgie/Noddy Stick Keeler PN: 2301-P-1014 An ideal orthoptic aid specifically designed for children’s fixation during the prism and cover test and other orthoptic assessments. It has attractive coloured pictures on one side (policeman and coloured budgie) and two reduced test types and a passage of N5 reading type on the reverse. Made in UK
  • Maddox_Wing_Test
    Maddox Wing Test   Convenient hand held, quick and efficient near test for heterphoria which is measured on the red vertical scale. Esophoria and exphoria are measured by the white horizontal scale. Cyclophoria may be assessed by moving the red arrow pointer parallel to the horizontal scale. The Maddox Wing is a hand-held device that is used to measure the degree of heterophoria at near. The device consist of a septum to dissociate the two eyes and a separate slit aperture for each eye. One eye sees a graduated vertical and horizontal scale, calibrated to read in prism dioptres, and the other eye sees a white arrow pointing upward and a red arrow pointing horizontally. Fusion is avoided because the eyes are viewing very different images; the eyes therefore adopt the passive position. The patient reports the numbers at which the arrows are pointing, giving a direct measure of the degree of vertical and horizontal phoria. The name Maddox Wing derives from the wing-like appearance of the device.
  • Random_Dot2_lg
    Designed to rapidly test for amblyopia and strabismus in early and non-readers and non-verbal children& adults. Expanded Random Dot Lea Symbols Test (500, 250, 125 seconds of arc). Graded circle test now down to 12.5 seconds with no monocular clues. New improved booklet has answer key on back cover and includes polarized viewers.
    • Expanded Random Dot Lea Symbols Test
    • Graded circle test now down to 12.5 seconds
    • No monocular clues with NEW technology
    • New improved booklet
    • Imprinted images inside booklet for matching
    • Answer Key on back cover